Skip to content
DOWNWAY

Shrink fit and press fit calculator

Assembly temperature, contact pressure and torque.

Loading simulator…

About this simulator

Set interference and hub dimensions: the simulator calculates how hot the hub must get to slide on with clearance, the pressure after cooling and how much torque the fit holds without a key. The chart shows stresses from bore to rim.

Formulas used

  • ΔT = (δ + folga) / (α · D)
  • p = (δ/D) / [ (1/Eh)·((Do²+D²)/(Do²−D²) + νh) + (1−νs)/Es ]
  • T = μ · p · π · D² · L / 2

An educational and preliminary sizing tool. Results don't replace standards, manufacturer catalogs or a responsible engineer's analysis.

FAQ

Heat the hub or cool the shaft?

Heating the hub is most common. When the required temperature could affect heat treatment, the shaft is cooled, for example with dry ice or liquid nitrogen.

More simulators